Signal Conditioning
|
Strain/Pressure
Sensors - Wideband (>100kHz) |
MODEL |
|
Four
Channel Wideband Strain Conditioner |
|
|
|
|
|
FEATURES |
|
|
|
|
DC
to 400 kHz Frequency Response |
|
Compact Rugged Enclosure |
Bridge
Completion w/Remote Sense |
|
Local or Remote Shunt
Calibration |
|
Programmable
Excitation Voltage |
|
QUICK
SPEC. |
Programmable Gain:
x1 to x10,000 |
Frequency
Response: DC to 400 kHz |
CMMR: 80dB @ 100
Hz |
Excitation
Voltage: 0.1 to 10.0 Volts |
Low Pass Filter:
Digital, 10 Hz to 100 kHz |
Accuracy: 0.05% |
|
|
|
|
MODEL |
|
Wideband
Programmable Strain Conditioner |
|
|
|
|
|
FEATURES |
|
|
|
|
DC
to 500 kHz Frequency Response |
|
±300 Volt
Common Mode |
User
Configurable Bridge Completion |
|
Integral Isolated
Power Supplies |
|
Dual
Outputs |
|
QUICK
SPEC. |
Programmable Gain:
x1 to x10,000 |
Frequency
Response: DC to 500 kHz |
CMMR: (G=1000) 120dB
@ 60 Hz |
Excitation
Voltage: 0.1 to 10.0 Volts |
Low Pass Filter:
6 User Configured Plug-in |
Bridge
Completion: 8 Position User Configured |
|
|
|
|
MODEL |
|
Four
Channel Automated Strain Conditioner |
|
|
|
|
|
FEATURES |
|
|
|
|
Compact
Rugged Enclosure |
|
Auto Balance and Auto
Gain |
Bridge
Completion w/Remote Sense |
|
Local or Remote Shunt
Calibration |
|
Programmable
Excitation Voltage |
|
QUICK
SPEC. |
Programmable Gain:
x1 to x50,000 |
Frequency
Response: DC to 100 kHz |
CMMR: 80dB @ 100
Hz |
Excitation
Voltage: 0.1 to 10.0 Volts |
Low Pass Filter:
Digital, 10 Hz to 100 kHz |
Accuracy:
0.05% |
|
|
|
|
MODEL |
|
Precision
Strain Conditioner |
|
|
|
|
|
FEATURES |
|
|
|
|
DC
to 100 kHz Frequency Response |
|
±300 Volt
Common Mode |
User
Configurable Bridge Completion |
|
Integral Isolated
Power Supplies |
|
Dual
Outputs |
|
QUICK
SPEC. |
Gain Range: x1 to
x2,500 |
Frequency
Response: DC- 100 kHz |
CMMR: (G=1000) 120dB
@ 60 Hz |
Excitation
Voltage: 0.1 to 15.0 Volts |
Low Pass Filter:
1, 3, 10, 30, ...30 kHz |
Bridge
Completion: 8 Position User Configured |
|
|
|